FEATURES - Lightweight
- Dual output
- 3.5 kW /120 VAC for electronics - 6.5 kW / 240 VAC for AC systems
- Replace 600 lbs, 10 kW APU with 60 lbs inverter
- Mounting options: deck (tunnel) or rack
- Meets or exceeds:
- MIL-STD-1275B, 28 VDC vehicle power - MIL-STD-1332B, power quality - MIL-STD-461E, full army ground requirements
|
 |
|
|
| Voltage | 28 VDC nominal (18-32 VDC) | | Current | 600 Amps max | | DC Power Disturbances | MIL-STD-1275B |
| |
| Applicable standards | MIL-STD-1332B Class 2B | | Configuration | dual phase, grounded neutral | | Output | 120 VAC, 1Ø | 240VAC, 10 (optional 3Ø available) | | Rated power factor | 0.8 | 0.8 | | Output power | 3500 W | 6500 W | | Output VA | 4375 VA | 8125 VA | | Rated output current | 36.5 A | 33.9 A | | Voltage regulation | 3% | | Frequency | 60 +/- 0.06 Hz | | Waveform deviation | 5% | | Efficiency at rated load | 84% | | Harmonic distortion | 2% |
|
Electromagnetic interference/ electormagnetic compatability (EMI/EMC) | MIL-STD-461E Army Ground | | Vibration | MIL-STD 810F, Category 20, 24 | | Audible noise | 75 dBA at 36 in (0.9 m) | | Shock (transit drop) | MIL-STD-810F, procedure IV | | Operating Temperature | -25°F to +138°F(-32°C to +59°C) | | Storage Temperature | -60°F to +160°F(-51°C to +71°C) | | Blowing rain | MIL-STD-810F, 45 degrees, 4 inches per hour (10 cm/hr) | | Sand and dust | MIL-STD-810F, blowing dust, blowing sand 1400 mg / cubic meter | | Relative humidity | up to 95% |
|
| (LXWXH Inches) | 23.5 L x 16.4 W x 6.96 H inches | | (LXWXH MM) | 59.69 L x 41.66 W x 17.68 H cm | | Weight | | (LBS. Max) | 60 lbs | | (KGS. Max) | 27.2 kgs |
|