- Mean time between failures (MTBF) – 40,000 hours
- Interleaved parallel operation of DC-DC converters
- Ability to load share among multiple units
- Monitoring of the RPS using digital signal processing implemented on an embedded microprocessor platform
- Use of insulated gate bipolar transistors (IGBT) as power switching devices
|
 |
|
| Applicable standards | MIL-STD-1399, Section 300 | | Voltage | 440 VAC nominal, 3 phase | | Frequency | 60 Hz nominal |
|
| Applicable standard | MIL-P-15736D, MIL-P-15736/5 | | Voltage | 28 VDC | | Continuous Current Rating | 300 A | | Efficiency | 80% at rated load |
|
| Operating Temperature | 0°C to 50°C / 32°F to 122°F | | Humidity | up to 95% | | EMI/EMC | MIL-STD-461D | | Vibration | MIL-STD-167-1, Type 1, 4 Hz to 33 Hz | | Shock Resistance | MIL-S-901D, Grade A, Class I, Type A | | Airborne noise | MIL-STD-740-1, Grade B | | Cooling Method | Forced air convection |
|
| (LXWXH Inches) | 24.1 x 22.6 x 36.8 | | (LXWXH MM) | 613 x 574 x 935 | | Weight (Inclusive of Batteries) | | (LBS. Max) | 639 lbs | | (KGS. Max) | 290 kgs |
|